MicroFLOAT Modular Tap Extensions

Directions for Use

  • Select the MicroFLOAT chuck required for your machine spindle.
  • Slect the modular adapter size and number of extensions needed for your tapping applicaitons.
  • Start tapping at 100% of pitch feed. If issues occur, program 3/5% below the pitch feed. This will engage more tension to ensure the tap does not "drag" coming out.

 

Modular Bodies

Part No.
Description
L
D
d
23411-MOD
Modular Body MicroFLOAT #1
.20"
.91"
.79"
23611-MOD
Modular Body MicroFLOAT #2
.28"
1.38"
1.26"

Modular Extensions

Part No.
Description
L
D
Chuck
42150-25
1" Modular Extension #1
.98"
.91"
23400-..
42150-50
1" Modular Extension #1
1.97"
.91"
23400-..
42250-50
2" Modular Extension #2
1.97"
1.38"
23600-..
42250-100
2" Modular Extension #2
3.94"
1.38"
23600-..

ER Modular Adapters

Part No. Description L D d
42147-ER16 ER16 Modular Adapter #1 1.97" 1.10" .91"
42247-ER25 ER25 Modular Adapter #2 3.11" 1.65" 1.38"